《上海计量测试》2018年第2期
Vol.45,No.2 April 25,2018
不同探测器便携式X、γ辐射剂量当量(率)仪的计量特性
王遥 唐方东 白雪 孙训 袁杰(2)
Metrological performance comparison of portable X and Gamma radiation dose equivalent (rate) meters in different detector types
Wang Yao,Tang Fangdong,Bai Xue,Sun Xun,Yuan Jie
油气回收装置对燃油加油机计量性能的影响
张进明 李海洋 朱碧玉 田爽(5)
Study on the influence of Oil Vapor Recovery Device on the metering performance of fuel dispenser Zhang Jinming,Li Haiyang,Zhu Biyu,Tian Shuang
几种用于生物样品的拉曼光谱承载基底的光谱分析及基底选择标准 张人(9)
Spectral analysis of several Raman carrier substrates for bio sample application and selection criteria of substrates Zhang Ren
用统计量t检验使用中标准物质的量值 龚飞雁 罗旻泓(13)
Using t statistic to test the value of the standard reference materials in use
Gong Feiyan,Luo Minhong
超长型玻璃液体温度计的计量方法及不确定度评定 李强光 王晓丹 蒋静 田昀(16)
The measurement methods of lengthened glass thermometer and uncertainty evaluation
Li Qiangguang,Wang Xiaodan,Jiang Jing,Tian Yun
复合真空变送器的校准及不确定度分析 刘贝贝 张书令 许红 张忠立(20)
Calibration and uncertainty analysis of Composite vacuum transmitter
Liu Beibei,Zhang Shuling,Xü Hong,Zhang Zhongli
高压介质损耗测量仪量值溯源校准 沈明炎 肖娜丽 董小龙(23)
Research on traceability calibration of high voltage dielectric loss tester
Shen Mingyan,Xiao Nali,Dong Xiaolong
激光线长测量仪示值误差的校准装置 王树刚 刘亚俊(26)
Study on the calibration device for the indication error of the length meter with laser-based measurement Wang Shugang,Liu Yajun
红外光谱在绿松石鉴定中的应用 顾星宇 秦晓玲 戴正之 吕晓瑜(29)
Application of in infrared spectroscopy in turquoise identification
Gu Xingyü, Qin Xiaoling,Dai Zhengzhi,Lü Xiaoyü
高效液相色谱法测食品中的阿斯巴甜新旧国标方法的比对 周瑾(34)
The contrast between the new and the old national standard method Determination of aspartame in food by HPLC Zhou Jin
不同的稳定性评估方法对量值比对结果的影响 孔繁栋 陈超 王灿 任学弟(37)
The effect of different stability calculation methods on the results of quantity comparison Kong Fandong,Chen Chao,Wang Can,Ren Xuedi
炮筒式机动车仪表电磁场分析 莫南 金善益 王焕英(40)
The analysis and research of electromagnetic field for gun-barrel type automobile tnstrument cluster Mo Nan,Jin Shanyi,Wang Huanying
皂膜流量计校准中湿度的修正 朱碧玉 陈超 张进明(43)
Study on humidity correction in the calibration of soap film flow meter
Zhu Biyü,Chen Chao,Zhang Jinming
ANDOR SR-500型光栅光谱仪的波长校准方法
姚志明 严维鹏 段宝军 宋岩 韩长材 马继明 宋顾周(45)
Research on wavelength calibration algorithm for ANDOR SR-500 Grating Spectrometer Yao Zhiming,Yan Weipeng,Duan Baojun,Song Yan,Han Changcai,Ma Jiming,Song Guzhou
电荷放大器滤波设置对加速度计相移测量结果影响的仿真与验证 刘一 武泽(48)
Simulation and experiment of influence from filter setting of charge amplifier on measuring phase shift of accelerometer Liu Yi,Wu Ze
应用ANSYS软件分析温度对测量半球形薄壁零件尺寸的影响
徐剑桥 管宇旻 汤亚杰(51)
Analysis of the influence of temperature on the measurement of hemispherical thin-wall parts based on ANSYS Xü Jianqiao, GuanYumin,TangYajie
直流电子负载的工作原理及使用方法 张毅 丁鼎(54)
Discussions on the working principle and usage method of DC electronic load
Zhang Yi,Ding Ding
西藏自治区日喀则地区医用超声源强制检定情况分析 黄天浩 叶菁 赵智慧(56)
The analyzation of medical ultrasonic equipments’ compulsory verification in Xigaze City, Xizang Autonomous Region
Huang Tianhao,Ye Jing,Zhao Zhihui
二维码技术在检验报告中的应用 沈昱 徐微(58)
Application of Two-dimensional code technology in inspection report
Shen Yü, Xü Wei
投稿须知 (60-61)
0页 新年致辞
扉页 计量动态 两项科研成果喜获“上海市科技进步奖
扉页 计量动态 浦东新区领导来上海市计量测试技术研究院调研
28 计量动态 第二次中韩法制计量合作委员会会议在沪召开
53 计量动态 国家质检总局召开民用“三表”计量管理技术座谈会
广告索引
封二:上海市计量测试技术研究院机械与制造计量技术研究所
封四:上海市环境保护产品质量监督检验总站
前插一:上海市计量测试技术研究院机械与制造计量技术研究所
前插二:上海市计量测试技术研究院在线检测与通用计量技术研究所
前插三:上海市计量测试技术研究院在线检测与通用计量技术研究所
前插四:上海市计量测试技术研究院电子与电气计量技术研究所
前插五:上海市计量测试技术研究院电子与电气计量技术研究所
前插六:北京康斯特仪表科技股份有限公司
前插七:北京康斯特仪表科技股份有限公司